Back to all scenarios
Scenario #69
Cluster Management
K8s v1.20, GKE

Persistent Volume Expansion Failure

Expansion of a Persistent Volume (PV) failed due to improper storage class settings.

Find this helpful?
What Happened

The request to expand a persistent volume failed because the storage class was not configured to support volume expansion.

Diagnosis Steps
  • 1Verified the PV and PVC configurations.
  • 2Checked the storage class settings and identified that volume expansion was not enabled.
Root Cause

The storage class did not have the allowVolumeExpansion flag set to true.

Fix/Workaround
• Updated the storage class to allow volume expansion.
• Expanded the persistent volume and verified the PVC reflected the changes.
Lessons Learned

Ensure that storage classes are configured to allow volume expansion when using dynamic provisioning.

How to Avoid
  • 1Check storage class configurations before creating PVs.
  • 2Enable allowVolumeExpansion for dynamic storage provisioning.